> ## Documentation Index
> Fetch the complete documentation index at: https://docs.andromeda.ai/llms.txt
> Use this file to discover all available pages before exploring further.

# Alerts

> Alert rules, tiers, and Slack notifications.

Andromeda monitors clusters continuously and routes alerts to your team’s designated Slack channel. This page lists alert rules, meanings, routing behavior, and expected follow-up.

<Frame caption="Memory and pressure panels provide supporting context when host pressure or node alerts require impact review.">
  <img src="https://mintcdn.com/andromeda-44268052/kBEIeV6KxiDQm7zR/images/monitoring-alerting/memory-detail.png?fit=max&auto=format&n=kBEIeV6KxiDQm7zR&q=85&s=447c063251beafebcec89e5230013025" alt="Grafana memory dashboard with memory usage, OOM kills, huge pages, EDAC memory errors, swap usage, and memory pressure panels." width="1591" height="610" data-path="images/monitoring-alerting/memory-detail.png" />
</Frame>

<CardGroup cols={3}>
  <Card title="Alert tiers" href="#alert-tiers">
    Severity levels and examples.
  </Card>

  <Card title="GPU alerts" href="#gpu-alerts">
    Thermal, ECC, NVLink, PCIe, row remap, and XID signals.
  </Card>

  <Card title="Node alerts" href="#node-alerts">
    Readiness, reachability, cordon, drain, and pressure states.
  </Card>

  <Card title="Host alerts" href="#host-alerts">
    CPU, memory, I/O, network, disk, and temperature pressure.
  </Card>

  <Card title="Telemetry health" href="#telemetry-health">
    Metrics and logs freshness checks.
  </Card>

  <Card title="Expected chains" href="#expected-alert-chains">
    Follow-on signals that should appear after hardware faults.
  </Card>
</CardGroup>

## Alert tiers

| Tier   | Severity | Meaning                                                             | Example                                                                      |
| ------ | -------- | ------------------------------------------------------------------- | ---------------------------------------------------------------------------- |
| **t0** | critical | Cluster-wide emergency. Large-scale node loss or capacity collapse. | `ClusterMassLoss`, `ClusterNodeCapacityCritical`                             |
| **t1** | critical | High-impact job or capacity disruption. Immediate investigation.    | `TenantNodeCapacityCritical`, `LargeSlurmJobNodeUnhealthy`, `GpuCriticalXid` |
| **t2** | warning  | Degradation trending. Not an emergency but needs attention.         | `TenantNodeCapacityDegraded`, `GPUCorrectableEccErrorsHigh`                  |
| **t3** | info     | Individual node state changes. Informational.                       | `NodeCordoned`, `SlurmNodeDrained`                                           |

## Alert types

| Type          | Behavior                                                                      |
| ------------- | ----------------------------------------------------------------------------- |
| **edge**      | Fires once on state transition. No repeat. Used for hardware faults.          |
| **state**     | Fires while condition persists. Repeats at long intervals (24h for t0/t1).    |
| **sustained** | Fires after a condition persists beyond a `for` duration, such as 10m or 15m. |
| **aggregate** | Fleet-level threshold, such as >=50% nodes lost.                              |

## Slack behavior

Alerts fire once per state change. Slack does not post a separate “resolved” message for every alert; use the Alerts Overview dashboard in Grafana for current status.

When more than 5 events of the same type fire within 60 seconds, they are aggregated into a single Slack message.

## Cluster and capacity alerts

| Alert                         | Tier | Type      | Condition                                | Meaning                                                                                              |
| ----------------------------- | ---- | --------- | ---------------------------------------- | ---------------------------------------------------------------------------------------------------- |
| `ClusterMassLoss`             | t0   | aggregate | >=50% GPU nodes gone AND >=5 missing, 2m | Catastrophic cluster failure.                                                                        |
| `ClusterNodeCapacityCritical` | t0   | aggregate | >=10% nodes bad AND >=5, 2m              | Significant cluster degradation.                                                                     |
| `ClusterNodeCapacityDegraded` | t2   | sustained | >=5% bad AND >=3, 15m                    | Cluster health trending down.                                                                        |
| `TenantNodeCapacityCritical`  | t1   | state     | 0 ready nodes with >0 assigned, 5m       | All assigned nodes unavailable.                                                                      |
| `TenantNodeCapacityDegraded`  | t2   | sustained | >=10% bad AND >=2, 10m                   | Part of your assigned capacity is degraded.                                                          |
| `SlurmCapacityMismatch`       | t3   | sustained | Assigned != accounted, 15m               | Slurm and Kubernetes disagree on node count. Review in Grafana (informational; not posted to Slack). |
| `NodeCountDrift`              | t3   | sustained | Below 7-day peak, 1h                     | Node count dropped. Review in Grafana (informational; not posted to Slack).                          |

## GPU alerts

| Alert                          | Tier | Type           | Condition                                             | Meaning                                                 |
| ------------------------------ | ---- | -------------- | ----------------------------------------------------- | ------------------------------------------------------- |
| `GPUThermalThrottle`           | t2   | edge, 1h dedup | GPU temp > 83 °C                                      | GPU is thermal throttling. Performance degraded.        |
| `GPUMemoryThermal`             | t2   | edge, 1h dedup | HBM temp > 95 °C                                      | HBM overheating. Severe performance impact.             |
| `GPUNvlinkErrors`              | t2   | edge           | `increase(DCGM_FI_DEV_GPU_NVLINK_ERRORS[15m]) > 0`    | NVLink degradation. Affects multi-GPU jobs.             |
| `GPUUncorrectableEccErrors`    | t1   | edge           | `increase(DCGM_FI_DEV_ECC_DBE_*[15m]) > 0`            | Uncorrectable memory error. GPU will likely be drained. |
| `GPUCorrectableEccErrorsHigh`  | t2   | edge           | `increase(DCGM_FI_DEV_ECC_SBE_*[1h]) > 10`            | High rate of correctable errors. GPU degrading.         |
| `GPURowRemapFailure`           | t1   | edge           | `DCGM_FI_DEV_ROW_REMAP_FAILURE > 0`                   | Row remapping failed. GPU needs replacement.            |
| `GPUCorrectableRemappedRows`   | t3   | edge           | Row remapped due to SBE                               | Correctable error triggered a row remap. Informational. |
| `GPUUncorrectableRemappedRows` | t2   | edge           | Row remapped due to DBE                               | Uncorrectable error triggered a row remap.              |
| `GPUPcieReplayErrorsHigh`      | t2   | edge           | `increase(DCGM_FI_DEV_PCIE_REPLAY_COUNTER[15m]) > 50` | PCIe link instability.                                  |
| `GPUAllocatableDegraded`       | t2   | state          | GPU count dropped below 8 per node                    | Node has fewer GPUs than expected.                      |
| `GpuCriticalXid`               | t1   | edge           | Critical XID codes from host diagnostics              | Hardware GPU fault.                                     |

## Node alerts

| Alert                    | Tier | Type            | Condition                              | Meaning                                  |
| ------------------------ | ---- | --------------- | -------------------------------------- | ---------------------------------------- |
| `NodeNotReady`           | t2   | state           | `kube_node_status_condition{Ready}==0` | Kubernetes considers the node unhealthy. |
| `NodeUnreachable`        | t1   | edge, 30m dedup | Node unreachable                       | Node is completely unreachable.          |
| `NodeCordoned`           | t3   | state, 2m       | `kube_node_spec_unschedulable==1`      | Node marked unschedulable.               |
| `SlurmNodeDrained`       | t3   | state           | Slurm drain state set                  | Node pulled from Slurm scheduling.       |
| `SlurmNodeNotResponding` | t2   | state           | Slurm node not responding              | Slurm cannot reach the node.             |
| `NodeNetworkUnavailable` | t2   | state           | NetworkUnavailable condition           | Node networking is down.                 |
| `NodePIDPressure`        | t2   | state           | PIDPressure condition                  | Running out of process IDs.              |
| `NodeDiskPressure`       | t2   | state           | DiskPressure condition                 | Disk space critically low.               |
| `NodeMemoryPressure`     | t2   | state           | MemoryPressure condition               | System memory exhausted.                 |

## Host alerts

| Alert                          | Tier | Type           | Condition                               | Meaning                                                |
| ------------------------------ | ---- | -------------- | --------------------------------------- | ------------------------------------------------------ |
| `HostMemoryPressureHigh`       | t2   | sustained, 10m | PSI memory waiting >0.5 OR stalled >0.2 | Memory thrashing. Jobs will slow down.                 |
| `HostCPUPressureHigh`          | t2   | sustained, 10m | PSI CPU waiting >0.5                    | Severe CPU contention. Data loading bottleneck likely. |
| `HostIOPressureHigh`           | t2   | sustained, 10m | PSI I/O stalled >0.3                    | Storage I/O blocking processes.                        |
| `HostNetworkErrorsHigh`        | t2   | edge, 6h dedup | Network errors >10/s                    | Persistent network errors.                             |
| `HostNodeOvertemperatureAlarm` | t1   | edge           | Hardware thermal sensor alarm           | Physical hardware overheating.                         |
| `NodeDiskFillingUp`            | t2   | sustained      | Predicted to fill within window         | Disk will fill at current rate.                        |

## Log-derived alerts

These alerts also evaluate host log signals in addition to metrics:

| Alert                   | Tier | Type | Catches                                       |
| ----------------------- | ---- | ---- | --------------------------------------------- |
| `GpuCriticalXid`        | t1   | edge | 46 known critical GPU XID error codes         |
| `NvlinkError`           | t1   | edge | NVLink errors in host diagnostics             |
| `Mlx5DriverError`       | t1   | edge | Mellanox NIC driver errors                    |
| `LinkDown`              | t1   | edge | Network link down events                      |
| `MachineCheckException` | t1   | edge | CPU machine check exceptions (hardware fault) |

## Telemetry health

| Alert                 | Tier | Condition                          | Meaning                                                                                   |
| --------------------- | ---- | ---------------------------------- | ----------------------------------------------------------------------------------------- |
| `ClusterMetricsStale` | t2   | No metrics from cluster for 5+ min | Metrics are stale for this cluster—refresh Grafana; contact support if it persists.       |
| `ClusterLogsStale`    | t2   | No logs for 15+ min                | Host logs are stale for this cluster—retry log workflows; contact support if it persists. |

## Alert routing

When an alert fires, it is posted to your designated Slack channel. Related signals on the same node may be grouped so your channel stays readable.

## Expected alert chains

Hardware faults typically produce a sequence of alerts:

| Root cause                  | Expected consequence                | Within  |
| --------------------------- | ----------------------------------- | ------- |
| `GpuCriticalXid`            | `SlurmNodeDrained` + `NodeCordoned` | \~2 min |
| `NodeUnreachable`           | `LargeSlurmJobNodeUnhealthy`        | \~2 min |
| `GPUUncorrectableEccErrors` | `SlurmNodeDrained`                  | \~2 min |
| `MachineCheckException`     | `SlurmNodeDrained`                  | \~2 min |

If a root cause fires but the expected consequence does not appear within the expected window, escalate to [Andromeda Support](/support).